DB
Dennis ByrneLAB DIRECTOR

CoA-2026-00816FINALv1

City of Lebanon Water · 3 samples · 11 results · generated May 22, 2026 03:32

CoA Preview

Live PDF rendered from Prisma data

PDF

State EDD Exports

Electronic Data Deliverables — pre-formatted for each agency

Release info

ClientCity of Lebanon Water
StatusFINAL
Version1
GeneratedMay 22, 2026 03:32
ReleasedJun 7, 2026 03:32
Released byHarry Locker
Sample count3
Result count11
Exceedances0

AI Clinical Summary

v2 Preview

Composite analysis of 3 samples shows trace-level metals within EPA MCLs except one drinking-water sample with Pb above 15 µg/L action level.

Total Coliform positive in one CIP rinse sample; recommend immediate resampling and review of sanitation cycle.

Results in this report (11)

SampleMethodAnalyteResultRLFlag
ENV-2026-04775EPA 537.1Perfluorooctane SulfonateJ 1.66 ng/L2NONE
ENV-2026-04775EPA 537.1PFHxSJ 0.80 ng/L2NONE
ENV-2026-04775EPA 537.1PFNA< 22NONE
ENV-2026-04775EPA 537.1Perfluorooctanoic AcidJ 1.52 ng/L2NONE
ENV-2026-04776EPA 8260CBenzeneJ 0.22 µg/L0.5NONE
ENV-2026-04776EPA 8260CToluene0.64 µg/L0.5NONE
ENV-2026-04776EPA 8260CTrichloroethyleneJ 0.20 µg/L0.5NONE
ENV-2026-04776EPA 8260CTetrachloroethyleneJ 0.33 µg/L0.5NONE
ENV-2026-04776EPA 8260CMTBEJ 0.50 µg/L1NONE
ENV-2026-04776EPA 8260CVinyl ChlorideJ 0.28 µg/L0.5NONE
ENV-2026-04777SM 5210BBOD59.30 mg/L2NONE