DB
Dennis ByrneLAB DIRECTOR

COC-2026-0343

Chain of Custody · 1 containers · Sampling event SE-2026-0343

Project & Site

ClientBurlington Department of Public Works
ProjectPFAS Source Investigation — North End (BURL-PFAS-2026)
SiteRiverside Well #1 (BURL-PFAS-W1)
Site typedrinking well
SamplerJames Hartwell
CollectedMay 18, 2026 01:32
WeatherClear
Air temp19.1 °C

CoC barcode

Barcode COC-2026-0343
Code 128

Shipping & Cooler

CarrierEndyne Courier
TrackingEC-69914
Cooler IDCLR-862
Cooler temp blank2.3 °C
Tamper seals100697,100698
Seals intact on arrival

Field Readings

pH7.89
Cond (µS/cm)513
DO (mg/L)4.88
Temp (°C)10.2
ORP (mV)113
Turb (NTU)4.02

Captured per ISO 5667 at the point of collection

Groundwater Purge

Purge volume27.8 L
Drawdown0.45 m
Pump rate0.5 L/min
Stabilized3 well volumes

Low-flow purge per ASTM D6452

Custody transfers (1)

#Relinquished byRelinquished atReceived byReceived atSig from / to
1James HartwellMay 18, 2026 03:32Endyne CourierMay 18, 2026 04:13James Hartwell / T. Hill

Container manifest (1)

AccessionContainerPres.MatrixVolReceipt cond.pH chkTests
ENV-2026-04718250mL polypropyleneicedWATER250INTACTn/aEPA 537.1