<?xml version="1.0" encoding="UTF-8"?>
<NHDESDeliverable version="1.0">
  <Header>
    <LabName>Endyne Laboratories LLC</LabName>
    <LabCertification>ISO/IEC 17025:2017</LabCertification>
    <ReportCode>CoA-2026-00819</ReportCode>
    <GeneratedAt>2026-06-10T09:16:33.124Z</GeneratedAt>
  </Header>
  <Results>
    <Result>
      <Sample>ENV-2026-04769</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 8260C</Method>
      <Analyte cas="71-43-2">Benzene</Analyte>
      <Value units="µg/L" qualifier="J">0.2</Value>
      <RL>0.5</RL>
      <MDL>0.2</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04769</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 8260C</Method>
      <Analyte cas="108-88-3">Toluene</Analyte>
      <Value units="µg/L" qualifier="">0.9895222409903162</Value>
      <RL>0.5</RL>
      <MDL>0.2</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04769</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 8260C</Method>
      <Analyte cas="79-01-6">Trichloroethylene</Analyte>
      <Value units="µg/L" qualifier="J">0.2</Value>
      <RL>0.5</RL>
      <MDL>0.2</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04769</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 8260C</Method>
      <Analyte cas="127-18-4">Tetrachloroethylene</Analyte>
      <Value units="µg/L" qualifier="J">0.2</Value>
      <RL>0.5</RL>
      <MDL>0.2</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04769</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 8260C</Method>
      <Analyte cas="75-01-4">Vinyl Chloride</Analyte>
      <Value units="µg/L" qualifier="J">0.2528217137799098</Value>
      <RL>0.5</RL>
      <MDL>0.2</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04769</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 8260C</Method>
      <Analyte cas="1634-04-4">MTBE</Analyte>
      <Value units="µg/L" qualifier="J">0.8170892356360293</Value>
      <RL>1</RL>
      <MDL>0.5</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04770</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 8270D</Method>
      <Analyte cas="91-20-3">Naphthalene</Analyte>
      <Value units="µg/L" qualifier="J">0.5</Value>
      <RL>1</RL>
      <MDL>0.5</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04770</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 8270D</Method>
      <Analyte cas="50-32-8">Benzo[a]pyrene</Analyte>
      <Value units="µg/L" qualifier="U"></Value>
      <RL>0.1</RL>
      <MDL>0.05</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04771</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 6020B</Method>
      <Analyte cas="7439-92-1">Lead</Analyte>
      <Value units="µg/L" qualifier="">3.863844551632025</Value>
      <RL>1</RL>
      <MDL>0.5</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04771</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 6020B</Method>
      <Analyte cas="7440-38-2">Arsenic</Analyte>
      <Value units="µg/L" qualifier="">2.583052442320205</Value>
      <RL>1</RL>
      <MDL>0.5</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04771</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 6020B</Method>
      <Analyte cas="7439-97-6">Mercury</Analyte>
      <Value units="µg/L" qualifier="J">0.14028381443688</Value>
      <RL>0.2</RL>
      <MDL>0.1</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04771</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 6020B</Method>
      <Analyte cas="7440-43-9">Cadmium</Analyte>
      <Value units="µg/L" qualifier="">0.6306121988973439</Value>
      <RL>0.5</RL>
      <MDL>0.2</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04771</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 6020B</Method>
      <Analyte cas="7440-47-3">Chromium</Analyte>
      <Value units="µg/L" qualifier="">5.295465760000752</Value>
      <RL>2</RL>
      <MDL>1</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04771</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 6020B</Method>
      <Analyte cas="7440-50-8">Copper</Analyte>
      <Value units="µg/L" qualifier="">44.71079076982225</Value>
      <RL>2</RL>
      <MDL>1</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04771</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 6020B</Method>
      <Analyte cas="7439-89-6">Iron</Analyte>
      <Value units="mg/L" qualifier="">0.2114069987091304</Value>
      <RL>0.05</RL>
      <MDL>0.02</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04771</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 6020B</Method>
      <Analyte cas="7439-96-5">Manganese</Analyte>
      <Value units="µg/L" qualifier="J">1</Value>
      <RL>2</RL>
      <MDL>1</MDL>
      <Flag>NONE</Flag>
    </Result>
    <Result>
      <Sample>ENV-2026-04771</Sample>
      <Client>VHB Engineering</Client>
      <Project>VHB-MANCH-PH2</Project>
      <Site>VHB-MANCH-MW7</Site>
      <Matrix>WATER</Matrix>
      <Collected>2026-06-01T17:32:51.563Z</Collected>
      <Method>EPA 6020B</Method>
      <Analyte cas="7440-66-6">Zinc</Analyte>
      <Value units="µg/L" qualifier="">11.03994302494773</Value>
      <RL>10</RL>
      <MDL>5</MDL>
      <Flag>NONE</Flag>
    </Result>
  </Results>
</NHDESDeliverable>
